1. Introduction
→Applicable to pipes diameter less than 1500mm, for determination
of ring stiffness, ring flexibility, flattening, creep ratio
continuous test(1000h/42d), deflection properties, etc.
→ For original ring tensile test for fiber glass reinforced plastic
mortar pipes.
→ Application for pipes: PE pipes, UPVC pipes, CPVC pipes, PE-X
pipes, PP-R pipes, PB pipes, PS pipes, PAP pipes, SP pipes, PP
pipes, PPR pipes, ABS pipes, PVC-U double-wall corrugated pipes,
RPM pipes, FRPM pipes, polyethylene silicon core pipes, PVC-U
double wall corrugated pipes, etc.
Comply with standards:
→ EN 13476-1:2001 Plastics piping systems for non-pressure
underground drainage and sewerage-Structured-wall piping systems of
unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and
polyethylene (PE)- Part 1: General requirements performance
characteristics.
→ ISO9969:2007 Thermoplastics pipes -- Determination of ring
stiffness
→ GB/T9647Thermoplastics pipes-Determination of ring stiffness
→ GB/T18042 Thermoplastic plastic pipes creep ratio test method
→ GB/T14452 Metallic materials-Determination of bending mechanical
properties
→ GB/T18477.1 Unplasticized polyvinyl chloride (PVC-U) structure
wall pipline system for underground soil waste and drainage-Part1:
double wall corrugated pipes
→ GB/T21238 Glass fiber reinforced plastics mortar pipes
→ CJ/T270 Steel reinforced spirally wound Polyethylene(PE) drainage
pipe
→ JT/T529 Plastic bellows for prestressed concrete bridge
→ JG225 Corrugated metal ducts for prestressed concrete
→ Polyethylene structure wall pipeline system for underground usage
Part1:Polyethylene double wall corrugated pipes
→ GB/T19472.2 Polyethylene structure-wall piping system for
underground usage Part 2: Polyethylene spirally enwound
structure-wall pipes
Features
→ With inner diameter deformation measurment device for DN1500mm
pipes, high stiffness and stable gapless platens, 150% high
stiffness without a partial load resistance.
→ With precise gapless ball screw, high stiffness, good stability
double column loading frame.
→ High precise load cell, wide linearity, good stability to ensure
the accuracy of load.
→ Embedded with Ethernet interface, with hand-held controller,
flexible, switch freely.
→ Wide test speed 0.001-600mm/min.
→ With flexible Excel or Word report format to select, designate,
ranking, separate, merge, multi-type output.
→ Automatic return after test, intelligent, efficient and quick.
→ With multi-protection functions: overload, over current, over
voltage, wizard protection.
2. Technical Specification
No. | Items | Specification |
1 | Max. Test force | 30kN/50kN/100kN |
2 | Load class | Class 0.5/Class 1 |
3 | Measuring range of load | 0.4%-100%FS/1%-100%FS |
4 | Relative error of indicating value | Within ±0.5% |
5 | Load resolution | 1/±300000F.S |
6 | Measuring range of deformation | 0.2%-100% |
7 | Adjusting range of load rate | 0.005%-5%FS/S |
8 | Adjusting range of deformation rate | 0.005-5%FS/S |
9 | Control precision of deformation rate | Within ±1% |
10 | Adjusting range of displacement rate | 0.01-500mm/min |
11 | Control precision of displacement rate | Within ±0.2% of the set value |
12 | Test span | 510mm |
13 | Measuring range of pipes | 0-1500mm |
14 | Compression platen | 310mm*260mm |
15 | Power supply | 220VAC, 50Hz |
16 | Power | 2.0kW |
17 | Dimension (L*W*H) | 1050*640*2600mm |
If you face any problems in future during testing process we
promise we will give you a reply within 48 hours and solution
provide within 3 working days. We can offer operation video and
English operation muanual. We can provide video-con.
Onsite Service:
1.Device installation; 2.Equipment Operation Test Technology
training;3.Equipment Calibration;4.Daily maintenance and
maintenance of equipment
Free technical training for visiting factories
24-hour Online contact
Free software upgrades
Free information:
1.Product Instruction;2.Product operation
instruction/video;3.Experiment Test (test application, test report)
Device Problem Handling:
1. Social media 24 hours online communication;2. Mail Seamless
Docking;3. Video Conferencing;